Get a repair price
A local technician calls back with a time and a price before any work starts.
Rather talk? Call (815) 800-0677 or text us.
Short answer
Ready for a price?
Call, text, or send the form. A local technician gives you a price before any work starts.
Not cooling: check these first
Whirlpool's own checklist for a window or portable air conditioner that is not cooling, in order (Whirlpool):
- Is the outside temperature below 65°F (18°C)? Below that, the unit will not cool at all.
- Are the controls set correctly, and is the fan speed on Turbo or Turbo Cool for faster cooling?
- Does the filter need cleaning? Whirlpool says to check it every 2 weeks.
- Are the condenser coils dirty or obstructed by debris?
- Is Power Saver mode on? On some models it does not circulate room air continuously; use Low, High or Turbo instead.
- Are the louvers or vents blocked by curtains, blinds or furniture?
- Is the air conditioner sized correctly for the room?
For central air, the Department of Energy says a clogged filter restricts airflow and lets dirt reach the evaporator coil, cutting its heat-absorbing capacity, and that the outdoor condenser needs at least 2 feet of clearance from foliage and debris (Department of Energy).
Frozen coil
Carrier says a frozen evaporator coil almost always comes down to restricted airflow, a dirty filter, closed or blocked vents, a failing blower fan, or low refrigerant. Running the system against a fully iced coil strains and can damage the compressor. The fix: turn the unit off and let the ice melt completely (it can take several hours), replace the filter and clear the vents; if it freezes again, the cause is likely low refrigerant from a leak, which needs a technician (Carrier).
Leaking water
On a window or portable unit, Whirlpool's check is whether it is properly leveled: the air conditioner should slope slightly downward toward the outside so condensate drains away, not into the room. Do not drill a hole in the base or condensate pan (Whirlpool). On central air, the Department of Energy says to clear the condensate drain channel periodically with a stiff wire; a clogged drain can shut the system off or cause water damage where it overflows (Department of Energy).
Won't turn on
Whirlpool's checklist (Whirlpool):
- Is it plugged into a grounded 3-prong outlet?
- Is a time-delay fuse or breaker of the correct capacity being used?
- Has the power cord's own reset button tripped? Press and release RESET, listening for a click.
- Has a household fuse blown or a breaker tripped? Replace or reset it; call an electrician if it keeps happening.
- Is the unit actually switched on, with the Fan Speed control on an active setting?
If it keeps tripping the breaker, Whirlpool's causes are too many other things sharing the same circuit, the unit plugged into an extension cord (never use one with an air conditioner), or a power cord that is pinched, overloaded or aging. Wait at least 3 minutes after a trip before restarting (Whirlpool).
Short cycling
Carrier's common causes for an air conditioner that turns on and off without finishing a cooling cycle: a dirty filter restricting airflow until the system overheats and shuts down, low refrigerant, a thermostat that misreads the room or has wiring issues, an oversized system that cools the air too fast without removing humidity, and failing electrical components like a capacitor or relay (Carrier). Trane points to the same two leading causes: thermostat problems, including one mounted in direct sunlight, and a system that was sized wrong from installation (Trane).
Noisy fan
Whirlpool lists what counts as normal operating sound (Whirlpool):
- Water droplets pinging or clicking against the condenser; the water helps cool it.
- Air movement from the fan.
- Clicks from the thermostat cycling.
- A high-pitched hum or pulsing noise from a modern high-efficiency compressor cycling on and off.
- Sizzling, hissing or dripping from water hitting the defrost heater during the defrost cycle.
Grinding, squealing or metal-on-metal rattling is outside that list and points to the fan motor or blade, which needs a technician to open the housing.
Window, portable, mini-split and central air: what's different
A window or portable unit is fully manufactured, charged and sealed at the factory, which federal rules classify as a small appliance (40 CFR 82.152) and the cheapest to repair: Angi's 2026 guide puts it at $104 to $354, averaging $229 (Angi). A ductless mini-split has no ductwork, just an indoor head connected to an outdoor compressor by a line set, and Fixr prices its repairs at $300 to $1,000 (Fixr). Central air, ducted with an outdoor condenser and an indoor evaporator coil in the furnace plenum, runs the widest range, $150 to $2,000 (Fixr), since a compressor or evaporator coil replacement can run into the thousands. Mini-splits and central systems both use higher-pressure refrigerant and fall under a different EPA certification than a window unit.
Refrigerant work needs a certified technician
EPA Section 608 of the Clean Air Act requires certification for anyone who adds or removes refrigerant, or otherwise opens the sealed system, on equipment that could release it (EPA). Window and portable units, sealed at the factory with 5 pounds or less of refrigerant, are Type I, small appliances; central air and ductless mini-splits are higher-pressure systems and fall under Type II (EPA, 40 CFR 82.152). Venting refrigerant on purpose is prohibited (EPA). This site is not itself a licensed HVAC contractor; refrigerant work goes to a licensed local technician certified for the equipment type. Ask to see the card before any refrigerant work starts.
What the repair usually costs
- Service call or diagnostic: $75 to $200
- Capacitor replacement: $100 to $250
- Thermostat replacement: $140 to $350
- Condenser fan motor replacement: $200 to $700
- Refrigerant leak find-and-repair: $200 to $1,500
- Compressor replacement: $600 to $2,500
- Evaporator coil replacement: $1,000 to $4,500
Figures from HomeGuide, 2025. By type, window units run $75 to $350, portable $80 to $350, ductless mini-split $300 to $1,000, and central air $150 to $2,000 (Fixr, 2026).
Repair or replace
InterNACHI's life expectancy chart gives a window air conditioner 5 to 7 years and central air 7 to 15 years (InterNACHI). Angi's rule of thumb: a new window unit runs $140 to $525, and if the repair costs more than half of that, replacing is usually the better math (Angi). The same logic applies to central air, where a single evaporator coil replacement can run $1,000 to $4,500, a meaningful share of a new system's cost.
Rockford's summers
Rockford's official 1981 to 2010 climate normals, built from NOAA data, put the average July high at 84.5°F and the average July temperature at 73.8°F, both the warmest of the year. July also carries the most cooling degree days of any month, 274, more than double June's 175. The station averages about 5.7 days above 90°F in July, 4.0 in August and 3.4 in June, roughly 13 days a year of 90°F-plus heat (Illinois State Climatologist). That is why a dirty filter or a slow refrigerant leak that goes unnoticed in May turns into an emergency call in July.
Sources: Whirlpool, air conditioner not cooling; U.S. Department of Energy, air conditioner maintenance; Carrier, will frozen AC fix itself; Whirlpool, air conditioner water dripping; Whirlpool, air conditioner won't turn on; Whirlpool, air conditioner trips circuit breaker or fuse; Carrier, what is AC short cycling; Trane, AC short cycling; Whirlpool, common noises and sounds for air conditioners; 40 CFR 82.152, definition of "small appliance"; U.S. EPA, Section 608 certification requirements; U.S. EPA, prohibition on venting refrigerants; Angi, window air conditioner repair cost (updated May 3, 2026); Fixr, AC repair cost (updated Jan 29, 2026); HomeGuide, AC repair cost (Aug 22, 2025); InterNACHI, Standard Estimated Life Expectancy Chart for Homes; Illinois State Climatologist, Rockford climate normals (1981-2010, NOAA data)
Where this is done
Air Conditioner Repair across Rockford and Winnebago and Boone counties. Prices for every appliance are on the appliance repair in Rockford homepage. Each town page has its own local rules and numbers; the rest are on the service area page.
Common questions
Air Conditioner Repair: questions
Why is my air conditioner running but not cooling?
Whirlpool's first checks: is the outside temperature below 65°F (it won't cool below that), are the controls set correctly, does the filter need cleaning, are the condenser coils dirty, and is Power Saver mode on. After those, it's usually airflow or refrigerant.
Why does my air conditioner have ice on it?
Almost always restricted airflow, a dirty filter, blocked vents or a failing blower, or low refrigerant, according to Carrier. Turn the unit off and let it thaw completely before running it again; running it against a frozen coil can damage the compressor.
Why does my air conditioner keep turning on and off?
Carrier and Trane call this short cycling. Causes include a dirty filter, a thermostat that misreads the room or is poorly placed, an oversized unit that cools too fast, low refrigerant, or a failing capacitor or relay.
How much does air conditioner repair cost in Rockford?
HomeGuide's 2026 guide averages $360, mostly $150 to $650. Window units run less, $104 to $354 averaging $229 on Angi's 2026 guide. Central air and ductless mini-splits run higher since the parts cost more.
Is it worth fixing an old air conditioner?
InterNACHI gives a window unit 5 to 7 years and central air 7 to 15. Angi's rule of thumb: if the repair costs more than half the price of a new unit, replacement is usually the better math.
Other appliances
Air Conditioner trouble?